For stylish home and office
CS385 / CS530B / CS730B / CS500B
CS385
CS530B
CS730B
* CS385B / CS530B / CS730B
CS385B / CS530B / CS730B
* Fully digitized microprocessor control
* Energy saving (UPS sleep mode )
* 50/60Hz frequency auto sensing
* Buzzer can be muted by pressing “ON/OFF” button
* Single PCB with reliable design
* Clear LED alarms
* Short circuit and overload protection
* Advanced battery management (ABM)
* Automatic diagnostics & battery check
* Surge protection of all outlets
* EMI/RFI noise filter
* Cold start (DC power on)
NEMA5-15 Only
Thailand,
Rear Panel
Model Name
CS 385B
CS 530B
CS 730B
OUTPUT
CS385B
UPS Capacity
No. of Sockets
385VA
530VA
730VA
NEMA 5-15R
UPS x 2, Bypass x 2
Breaker
Simulated sine wave at
Voltage
100V / 115V / 220V / 240V < +/- 5% AVR controlled by PWM
(on battery*)
Frequency (on battery)
50 or 60Hz +/- 0.3 Hz
< 10 milliseconds, including detection time
Battery
Transfer Time
Backup
INPUT
Voltage
100V +/- 20%, 110V +/- 25%
220V / 230V / 240V, 170V~280 at line input
50 or 60 Hz +/- 10% (auto sensing)
(single phase)
Bypass
Frequency
PROTECTION
Unit Input
Circuit breaker for overload & short circuit protection
UPS Automatic shutdown if overload exceeds 105% of
Overload Protection
nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds
UPS output cut off immediately
Short Circuit
Spike Protection
460 joules, 2ms
CS530B / CS730B
BATTERY
Type
Sealed, maintenance-free lead acid batteries with 3-5 years
typical life time
Breaker
Typical Recharge Time
6 hours
(to 90% of full capacity)
Back-up Time
Protection
PC with
15” LCD
8 - 12 minutes
15 - 18 minutes
Automatic self- test, Over discharge protection, short circuit
protection by fuse
Bypass
Battery
Backup
PHYSICAL
2.6 (5.72)
Net Weight kg (lbs)
Dimension WxDxH
INTERFACE
1.6 (3.52)
95 x 95 x 158 mm
2.6 (5.72)
95 x 138 x 158 mm
Sends battery low & power failure signals, and receives shutdown signal from computer
Detects power failure battery low, Schedules UPS ON / OFF, displays AC input / output power status
Dry Contact (option)
USB (option)
ALARM
Battery Backup
Short beeping sound every 4 seconds
(Buzzer can be muted by pressing main switch button)
Rapid beeping sound every seconds
Battery Low
UPS Works at Full Load
Overload
Long continuous beeping sound every 4 second
Continuous beeping sound
ENVIRONMENT
Ambient Operation
3,500 meters max elevation, 0-95% humidity
(No-condensing water),0-40 deg C
<40dBA (1 meter form surface)
Audible Noise
* See VS1000C on page 6
Download from Www.Soman3ua.ls.com. All Manuals Search And Download.
|
Miele Coffeemaker 9741510 User Manual
Miele Microwave Oven H 4042 BM User Manual
NAD CD Player T 751751 User Manual
NETGEAR Network Card EN516 User Manual
Nokia Cell Phone 2116 User Manual
Omega Vehicle Security Electric Heater PHCN 410 User Manual
Panasonic Car Video System CQDRX900U User Manual
Panasonic Electric Shaver ES7032 User Manual
Panasonic Network Card 2SB0792A User Manual
Paradyne Beverage Dispenser 8310 MVL User Manual